V6.0.0 ====== - FEATURES • Support for E1.37-7 RDM Endpoint PIDs. Previously only a draft version of the specification was implemented. • RDM Integrity (Test-suite) Improvements in RDM handling resulting in improved test results for the RDM Integrity test-suite which in turn leads to an even more robust RDM implementation. • DMX Fail Mode and DMX Startup Mode with Use the latest LuminetMonitor to configure this. The port LED’s will indicate when these modes are active, the power LED will be blue when one of these modes are configured (custom settings = settings that cannot be done using the front panel). When these modes are active (not the same as ‘configured’), RDM communication with the LumiSplit is possible, but not with other RDM devices connected to the output ports of the LumiSplit. (This is the exact same behavior as when using LTP, HTP or regeneration). Fail Mode en Startup Mode are possible when using the ‘Splitter’ functionality or the ‘Backup’ functionality. - BUG FIXES • Fixed the RDM discovery response Fixed the RDM discovery response algorithm to work with the Martin M-series. • Configure the backup timeout It is now possible to configure the backup timeout (in miliseconds) and backup auto-recovery using RDM. Go to the ‘Custom’ tab in LumiNet Monitor RDM settings.